IO Card PLC Signal Amplifier Board NPN to PNP Mutual Input Optocoupler Isolation Transistor Output Relay Module

IO Card PLC Signal Amplifier Board NPN to PNP Mutual Input Optocoupler Isolation Transistor Output Relay Module

  • R 750.00
    Unit price per 
  • Save R 750
Tax included.

SKU:

Technical Parameters:
 
Control voltage: DC3.3-24V
Input current: 5-10mA
Output type: non-contact type
Drive component: P/N channel FET
Maximum output current: 6A
Output voltage: DC5-24V
Operating time: 1ms or less
Reset time: 1ms or less
Maximum switching frequency: 2000Hz
Horizontal group installation: standard rail mounting

Instructions:


X1~X7 are the access terminals of the trigger signal.
S/S is the selection terminal for the high and low levels of the trigger signal.
 
E.g:
 
When the trigger signal is high, then the S/S terminal should be connected to the negative terminal corresponding to the trigger signal.
Conversely, when the trigger signal is low, the S/S terminal should be connected to the positive pole corresponding to the trigger signal.



Package includes:

1 x Relay module