FR2060 Non-contact Normal Reverse Phase Inspect Meter for Simple Check Lack of Phase Judgment Open Circuit Search
Description:
- The FR2060 non-contact phase detector is a major breakthrough in the traditional phase order detection method. In the traditional phase order detection, the terminal of the three-phase wire must be removed, and the three exposed clips or test pins of the phase order meter must be connected to the exposed 3 live wires, and FR2060 adopts clamp-shaped non-contact inductive measurement. There is no need to remove the wires or touch the high-voltage exposed live wires. Directly clamp the three ultra-inductive high-insulation clamps to the insulation skins of the three-phase live wires to detect phases. At the same time, sound and light indicate the positive or negative state of the phase order of the three-phase power supply.
- The FR2060 non-contact phase detector also has functions such as live line inspection, simple power inspection, open circuit search, break point positioning, and line maintenance.
- The FR2060 non-contact phase detector detects fast and convenient, and the display is clear at a glance, greatly improving the safety of field testing, effectively protecting the personal safety of operators, and increasing productivity! It is a safety instrument for three-phase power supply phase order, motor detection, and line maintenance!
Specification:
Function |
Phase detection (normal phase, reverse phase), live line inspection, simple electricity inspection, phase loss judgment, circuit breaker search, break point location, and line maintenance. |
Power |
9V battery, continuous use time is about 70 hours. |
Measure mode |
Non-contact clipping method |
Wire position |
The measured wire is in the center of the jaw |
Frequency |
50Hz/60Hz Automatic Identification |
Live electricity range |
AC70~1000V,45/65Hz(Sine wave continuous input),Conducted electrostatic detection |
Measuring the highest voltage |
AC1000V |
Clamp wire size |
Outside diameter ø1.5mm~ø48mm |
Display |
[Positive phase]4 phase detector lights are turned on in a clockwise direction; |
[Reverse phase]4 4 phase detection lights are turned on counterclockwise; | |
[Live electricity]L1, L2, L3 lights in the voltage setting range; | |
[Lack of phase]L1 or L2 or L3 lights are not lit; | |
[Open circuit]L1 or L2 or L3 lights are not lit | |
Beep |
[Positive phase]The instrument emits intermittent short beep; |
[Reverse phase]The instrument emits a continuous long beep. | |
Battery check |
After the power is turned on, the power indicator is on; the battery is low; the LOW BATTERY lamp is on. |
Clamp lead length |
0.6m |
Instrument size |
L 117.6mm?W 81mm?T 25mm |
Automatic shut-down |
After about 6 minutes of power on, the meter automatically shuts down to reduce battery consumption. |
Battery voltage |
When the battery voltage drops to about 5.2V, the battery voltage is low symbol to remind to replace the battery |
Instrument weight |
Instrument:260g(including battery) |
Maximum rated power |
300mVA |
Working temperature and humidity |
-10?ƒ~55??below 80%rh |
Storage temperature and humidity |
-20?ƒ~60??below 90%rh |
Insulation strength |