W2026C DC 12V 10A Digital Hygrometer Humidity Meter with Red/Blue LED Display Hygrometer Adjustable Humidity Controller Sensor Switch
Tax included.
Specifications:
Control humidity range: 1%RH-99%RH
Load power: 10A/DC12V
Humidity measurement range: 1% RH-999% RH
Measurement error:±3% RH (good environment temperature is 25??
Control humidity accuracy: 1% RH display: 1% RH
Humidity return: adjustable between 1-50% RH
Supply voltage: DC12V
Output type: 10A relay output
Probe type: humidity resistance sensor
Size: 48*29*22mm
Installation hole: 46*27m
Moisture control object: dehumidification or humidification
Probe line length: 1.5m line length
Working environment: humidity 90% RH no frosting
Parameter Code and Settings:
Code |
Description |
range |
Factory settings |
P0 |
Humidification/dehumidification |
H/C |
C |
P1 |
Backlash |
1-50%RH |
|
P2 |
Set the maximum limit |
99 |
95 |
P3 |
Set the minimum limit |
1 |
5 |
P4 |
Temperature correction |
-10 |
10 |
P5 |
Delayed start |
0-10 |
1 |
P6 |
Restore Factory settings |
ON- OFF |
OFF |
Setting Instructions:
1.Connect the power supply and load to power the controller. The red color above shows the humidity, blue below is displayed as the desired humidity
2. Press STG (+) ENT (-) to set the required humidity,After the setting is completed, wait for 3 seconds to automatically confirm the return. At this time, the controller automatically performs relay energization according to the setting.
3. Press and hold SET for 5 seconds to enter the main menu settings, press SET (+) ENT (-) to switch P0-P8, when adjusting parameters P0-P8 parameters
4. If you need to adjust P0, press SET button (+) ENT (-) at the same time, adjust 0K, then control SET (+) ENT (-)
Note: For 10A relays, to meet high power loads, please make sure the line is correct.
Indicator Description:
Indicator light: off means the relay is off, steady light means the relay is closed
Digital tube: The above shows that LL is the sensor open circuit, indicating that HH is out of the measurement range, the humidity will forcibly open the relay.
Package Included:
1 x W2026C DC 12V 10A Digital Hygrometer Humidity Meter